Specifications
Melt Volume Rate, MVR At 260°C/2.16 Kg: ???
UL Compliant, 94V-0 Flame Class Rating (3)(4): 1.8
Basic Infomation
Place of Origin: ——
Brand Name: S-Plastic Stat-kon
Certification: COA/ICP Test/Rohs/MSDS
Model Number: DX96717C
Payment & Shipping Terms
Packaging Details: 25KG/bag
Delivery Time: To be negotiated
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: To be negotiated
Product Description

S-Plastics Stat-kon DX96717C resin is a compound based on Polycarbonate resin containing Carbon Powder, Flame Retardant. Added features
of this material include: Electrically Conductive.

 


Property

TYPICAL PROPERTIES (1)      
MECHANICAL Value Unit Standard
Tensile Stress, yield 63 MPa ASTM D 638
Tensile Stress, break 54 MPa ASTM D 638
Tensile Strain, yield 5 % ASTM D 638
Tensile Strain, break 9.9 % ASTM D 638
Tensile Modulus, 50 mm/min 2480 MPa ASTM D 638
Flexural Stress 98 MPa ASTM D 790
Flexural Modulus 2890 MPa ASTM D 790
Tensile Stress, yield 61 MPa ISO 527
Tensile Stress, break 51 MPa ISO 527
Tensile Strain, yield 4.7 % ISO 527
Tensile Strain, break 11.1 % ISO 527
Tensile Modulus, 1 mm/min 2700 MPa ISO 527
Flexural Stress 98 MPa ISO 178
Flexural Modulus 2800 MPa ISO 178
IMPACT Value Unit Standard
Izod Impact, unnotched, 23°C 1831 J/m ASTM D 4812
Izod Impact, notched, 23°C 64 J/m ASTM D 256
Instrumented Impact Energy @ peak, 23°C 27 J ASTM D 3763
Izod Impact, unnotched 80*10*4 +23°C 123 kJ/m² ISO 180/1U
Izod Impact, notched 80*10*4 +23°C 9 kJ/m² ISO 180/1A
THERMAL Value Unit Standard
HDT, 0.45 MPa, 3.2 mm, unannealed 143 °C ASTM D 648
HDT, 1.82 MPa, 3.2mm, unannealed 131 °C ASTM D 648
HDT/Af, 1.8 MPa Flatw 80*10*4 sp=64mm 135 °C ISO 75/Af
PHYSICAL Value Unit Standard
Density 1.3 g/cm³ ASTM D 792
Moisture Absorption, 50% RH, 24 hrs 0.17 % ASTM D 570
Mold Shrinkage, flow, 24 hrs 0.7 % ASTM D 955
Mold Shrinkage, xflow, 24 hrs 0.7 % ASTM D 955
Mold Shrinkage, flow, 24 hrs 0.75 % ISO 294
Mold Shrinkage, xflow, 24 hrs 0.75 % ISO 294
Moisture Absorption (23°C / 50% RH) 0.25 % ISO 62
ELECTRICAL Value Unit Standard
Surface Resistivity 1.E+04 - 1.E+08 Ohm ASTM D 257
FLAME CHARACTERISTICS Value Unit Standard
UL Compliant, 94V-0 Flame Class Rating (3)(4) 1.8 mm UL 94 by GE
Source GMD, last updated:10/01/2004    

Processing

Parameter    
Injection Molding Value Unit
Drying Temperature 120 °C
Drying Time 4 hrs
Maximum Moisture Content 0.02 %
Melt Temperature 305 - 325 °C
Front - Zone 3 Temperature 320 - 330 °C
Middle - Zone 2 Temperature 310 - 320 °C
Rear - Zone 1 Temperature 295 - 305 °C
Mold Temperature 80 - 110 °C
Back Pressure 0.2 - 0.3 MPa
Screw Speed 30 - 60 rpm
Source GMD, last updated:10/01/2004  

 


Other related products we recommend:

For more information please download the datesheet

S-Plastic Stat-kon DX96717C a compound based on Polycarbonate resin containing Carbon Powder, Flame Retardant. Added feature 0  S-Plastics Stat-kon DX96717C.pdf

 

Get The Latest Quotation

 

First-level distribution source in South China

Reduce procurement costs, improve supply stability,

Help you find the most suitable engineering plastic materials

 

S-Plastic Stat-kon DX96717C a compound based on Polycarbonate resin containing Carbon Powder, Flame Retardant. Added feature 1Click to consult and get the latest quotation within 24 hours!

Recommended Products
Get in touch with us
Tel : 86-13925273675
Characters Remaining(20/3000)